Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is a DLC?[just dont reply its a Dual loop
controller!] Plz do Explain the advantage of DLC over PLC?

Answer Posted / manju & raju

THis one Correct

PLC means Programable Logic Controler.
Using PLC in Synchronizing Panel Because Load Sharing Purpus.



I think,

DLC Dual Loop Controle

Is This Answer Correct ?    6 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.

4172


what is the effect of power factor of machines in starting current

2055


how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?

2137


why the difference arise between HT reading & LT reading (submeters fixed in complexes, apartments etc)if the power factos exceed from 0.9 to 1 can the ht meter reads fast?

2961


What is true sine wave or pure sine wave inverter?? Is it sine wave or step wave?? If it is step wave, waves with how much step is considered as pure sine wave? Is it possible to produce pure sinewave using power electronics?

1869


temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%

1920


can the measured percentage error during calibration of single phase energy meter be negative?

2408


why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?

1796


why co incidence factor considered in transformer sizing?

1865


How to calculate LT XLPE CABLE for 11 kv / 433 v , 1000 kva oil type transformer system?

1919


why occ characteristics curve in not tracing back when we are bringing back the rhoestat?

1867


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2044


what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?

2387


What is synchro?

1168


generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...

1921