Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is RMU ?

Answer Posted / pavan kumar

RMU: Ring Main Unit. RMU used for H.T.side. RMU is having
3no.s of switches(Circuit Breakers or Isolators or LBS), it
is used for two inputs with mechanical or electrical
interlock and one outgoing to the load. Either one input
with two outgoings. RMU used for redundancy feeder’s
purpose.

Is This Answer Correct ?    279 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why front mounted CT polarities are always towards breaker?

1977


HOW CAN YOU CALCULATE PRACTICAL EFFICIENCY OF A ASYNCHRONOUS INDUCTIONMOTOR OF 7.5KW,& MOTOR IS RUNNING WITH AVOLTAGE OF 410 VOLTS,& TAKING CURENT OF 13 AMPS

1818


how we design a pannel to start 10HP motor with the help of star delta starter?

2144


What will happen if the voltage in my house drops from 220V to any lower voltage?

2120


what are all the components required to assemble solar panel other than pv cell?

1434


Why are short circuit ratings always 16kA,25kA,36kA and 50kA.Who has fixed these?

4221


It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.

3804


Maintenance of transformer???

2198


by using pump duty, how we will can calculate the motor duty(KW)? is there any standard or formula.

1923


1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?

2101


why the carbon brushes are broken in srim while the motor runningtime

1635


What are the uses of lead compensator?

1108


how invertor convert the dc into ac give brif detail

2084


is IS says that neutral should be brought to switch box. and this one is a recomended practice

1811


What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.

2257