every motors written in name plate IP 55 what is this?
Answer Posted / habeebm
IP (Ingress Protection) codes define how well an enclosure
protects against the external environment.
As the number gets higher, the protection gets better.
The first digit defines the protection level
against "solids", the second against "liquids". You MUST
use both digits to define an enclosure.
For the first digit:
0 = No protection
1 = Protected against objects greater than 50 mm diameter
2 = Protected against objects greater than 12 mm diameter
3 = Protected against objects greater than 2.5 mm diameter
4 = Protected against objects greater than 1.0 mm diameter
5 = Dust protected
6 = Dust tight
For the second digit:
0 = Not protected
1 = Protected against dripping water (i.e. vertical plane)
2 = Protected against dripping water up to 15 degree angle
3 = Protected against spraying water
4 = Protected against splashing water
5 = Protected against water jets
6 = Protected against heavy seas
7 = Protected against effects of immersion
8 = Protected against submersion
| Is This Answer Correct ? | 106 Yes | 8 No |
Post New Answer View All Answers
wish of these transformer uses oil?
why capacitive load is not used in routine life????any reason is there ??????
If I have 3 essential main switch board and 3 incoming electricity ,but only 1 genset running is that possible.
How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva
Dear Respected sir how to test ABB REX521 protection relay by relay tester.
what is positive , negative & zero equivalent system resistance
What is core CT & it's function?
63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate?
What is the formula to find out two phase active & reactive power
what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?
how to find the resistance and gap volatage of the diode??
How calculated single phase induction motor req. Capacitor?
What is the basic principal, by which DC voltage level is increased more than the supplied AC voltage during conversion. As upto AC level it is contorrled by firing anlge but after maximum level how is it possible.Please clear picture. OR we have to supply the higher level AC?
critically criticize the application of ring main unit in power system
how many Classification of fire extinguisher