Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is main parts of alternator.

Answer Posted / satya dev ( knight frank)

Main Parts- Stator,Rotor, Diode, windings, Pick up unit
Safety parts- AVR, CTs & PTs,
Movable Parts- Shaft,Cooling wheel,

Is This Answer Correct ?    20 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in non technical way how can u define POWER FACTOR??

1872


how to select correct size of power cable for inverter duty motor

1637


sugest any typical project ?

1865


What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw

1951


Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

2107


IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?

4215


what may the reason for vector shift in a generator?

1913


What is the difference between isolators and electrical circuit breakers?

1268


What are the various kind of cables used for transmission?

1145


why we have and use 3 phase not 2 or 4 or other in power system?

2167


What is the formula for calculating no-load current?

1144


WHAT ARE THE DISADTAGES OF SINGLE-WIRE-EARTH-RETURN SYSTEM USED FOR RURAL ELECTRIFICATION?

2015


Is there any question in the name of Static Switch in UPS??

2033


a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5

1749


1)What is a Triode? What are its uses? 2) What is a Triac? 3) What is a Thyristor?

2741