Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is main parts of alternator.

Answer Posted / satya dev ( knight frank)

Main Parts- Stator,Rotor, Diode, windings, Pick up unit
Safety parts- AVR, CTs & PTs,
Movable Parts- Shaft,Cooling wheel,

Is This Answer Correct ?    20 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why do we use copper cable for HT Supply and why not Aluminium?

2001


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2211


What is the diff. between single compression and double compression gland

1986


what is negative d.c. voltage, why this voltage is used in base transciever station.

2157


Why Neutral Isolation is required?

2228


what is meant by 3rd hormonics ?

2015


why booster transformer is used in sumpners test conducted on transformer????

3571


What is the role of feedback in a closed loop control system?

1072


HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?

2038


How to calculate the no of Ceiling fan (1200mm sweep) per unit area?

2067


How to calculate cable rating for 3 phase supply?

2174


How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva

1644


ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH

4153


Hello Friends, How can we recognize the CT Star Point is S1 or S2 in case of Electro Mechanical Relays and what is meant by Restraining coil in relays and what is the purpose of that.. thank you in advance..

2156


why we use single core 630mm2 cable for transformer secondary side

915