Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the role of link in neutral in a three phase ac
system?

Answer Posted / nbsubrahmanyam

In 3phase ac system ,In the case of link in neutral, we
should not use fuse.
(neutral is using at distribution level for getting single
phase or 3 phase 3wire 4wire system to supply the power to
the some loads),
Suppose we use the fuse in the neutral line,if any fault
or break occur in the neutral line, but current flows from
phase/line to load and come to neutral wire where it has
break,there will be a chance to shock to human
beings/workers who will do the works regarding the repairs.
we generally putting fuse in phase/line for protecting
the equipment/device from high voltages/currents.if any
fault occur in the phase/line ,current will not flows from
fuse,only it will come fuse hence there is no problem. but
in the case of neutral, the current flows through out
equipment that may lead to creat some problms as mentioned
above.

that's why we w should put only link for neutral in three
phase ac system.

Is This Answer Correct ?    22 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can anyone provide with a SLD for HT panel installation for a 33KV line and distribution end has three 1.5MV transformers. Is it suitable to use OCB or VCB and also provide me the suitable rating and its connection diagram.

3354


What is the earth treantment procedure?

2077


sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance

2100


what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....

1949


WHAT IS MEANT BY OVER EXCITATION IN GENERATOR TRANSFORMERS? DESCRIBE IT.

2707


how do prepare ongc exam.how is it question model.i am electrical. which part covering in electrical.tell me

2266


why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ??

2039


Why power genaration in India is at 50HZ while America its 60HZ

2289


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2044


how we can decide that what value of ht line will come to any commercial building? (ans except According to the building load)

1665


What happens if the series current double?

1476


plese send me the oces/dgfs sylabus and previous year question pattern of electrical engg.?

2305


What is d main advantage of using double circuit 3 phase transmission ?

1936


If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?

2066


what is frequency response?

1146