Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to control speed of DC motor with AC power?

Answer Posted / j.senthamizh

First we should be convert ac into dc using rectifier. Dc
motor speed control method classified into two 1.armature
control 2.field control . we are using armature control
method motor speed can be control below rated speed.or
using field control method the motor speed is above rated
speed. most people using armature control method because
field control method is dangerous than armature control
method.we are using field speed control at motor is running
condition and now field is open which times motor running at
dangerous speed. at the time motor bearing and shaft is
affected this condition.

Is This Answer Correct ?    24 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

induction 3 phase motor terminal connection

2654


how can we design robots

1944


why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?

2063


which type of cabel

2396


sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah

3963


IF % IMPEDANCE OF A TRANSFORMER IS INCREASED FROM 5.8% TO 8% HOW MUCH THE EFFICIENCY OF THE TRANSFORMER WILL COME DOWN?

2368


What tests should i carry over on a newly rewinded DC Generator with voltage rating of 38 volts and current rating of 350 amps, to certify that the machine is OK?

1867


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2041


what is the function of gss in the dg set.

1949


v/f drive basic princeple

2468


please send previous exams question papers

1817


i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1913


what is difference between 9kv 5ka surge arrester and 9kv 10ka surge arrester.

1850


What is the lower limit of break-down voltage of converter transformer.

1903


what is the difference betweem star connected motor & delta connected motor?

2353