How to control speed of DC motor with AC power?
Answer Posted / j.senthamizh
First we should be convert ac into dc using rectifier. Dc
motor speed control method classified into two 1.armature
control 2.field control . we are using armature control
method motor speed can be control below rated speed.or
using field control method the motor speed is above rated
speed. most people using armature control method because
field control method is dangerous than armature control
method.we are using field speed control at motor is running
condition and now field is open which times motor running at
dangerous speed. at the time motor bearing and shaft is
affected this condition.
| Is This Answer Correct ? | 24 Yes | 3 No |
Post New Answer View All Answers
induction 3 phase motor terminal connection
how can we design robots
why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?
which type of cabel
sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah
IF % IMPEDANCE OF A TRANSFORMER IS INCREASED FROM 5.8% TO 8% HOW MUCH THE EFFICIENCY OF THE TRANSFORMER WILL COME DOWN?
What tests should i carry over on a newly rewinded DC Generator with voltage rating of 38 volts and current rating of 350 amps, to certify that the machine is OK?
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
what is the function of gss in the dg set.
v/f drive basic princeple
please send previous exams question papers
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
what is difference between 9kv 5ka surge arrester and 9kv 10ka surge arrester.
What is the lower limit of break-down voltage of converter transformer.
what is the difference betweem star connected motor & delta connected motor?