why transmission line 11Kv OR 33KV,66Kv not in 10kv 20kv?
Answer Posted / kishore
FORM FACTOR of sine wave is 1.11
rms/avg=(im/root2)/(2*im/pi) = 1.11
FF of square wave is 1.00 n triangular is 1.15
so i think form factor is not the only logic behind
11kv/33kv but while the generator o/p formula suggest there
are certain terms multiplied with the form factor(1.11) n
it is forcibly made to a standadadised value by changing
certain parameters..
Is This Answer Correct ? | 34 Yes | 16 No |
Post New Answer View All Answers
List of equipments required foe industrial repair lab.
Why frequency changes due to load variation in power system ? i.e why when load increases frequency decreases?
What are IR values and what it should be for coil and for insulator
static chagre
. What is Electrical Life & Mechanical Life of Circuit Breaker? 2. What is Electrial Life & Mechanical Life of Magnetic Contactor? 3. What is RCD, RCCB & RCBO? 4. What is the Between defferance of RCD, RCCB & RCBO?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What will happen if i used 11KV earth ht kit to 11 KV / 11 KV cable termination?
what is rocking arrangement in arc heating
What type of wiring series or parallel is used for conventional and addressable type FAS & why?
What is the tipical Online UPS input voltage for 20 KVA load ( 3 Phase or 1 Phase )? Why ? Explain it...?
Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?
11KV AND 22KV NETWORK KW CAPACITY IN RING AND RADIAL?
when measure the core loss of three phase distribution transformer or three phase reactor loss, one phase shown negative watt loss. why??
Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.
I am an American living in Vietnam and I have recently gotten a refrigerator from Japan and it is rated for 100 vac, but the power here is 220 so I bought a voltage stabilizer it has a 1 kva output rating. Can you please tell me what the amperage is? I'm confused and without a working fridge.