Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between the HT Cable and LT Cable ?

Answer Posted / bk

Basic difference is the dielectric strength/ thickness of
insulation. For LV PVC is OK. However, for HT cable cross
linked poly ethylene(XLPE) is used.

Is This Answer Correct ?    214 Yes 35 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation

2044


What are the conditions for sustained oscillator or what is backhouse criterion?

1194


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2522


What is the use of oil in transformers?

1160


how to calculate current carring capacity of cable and cable selection? 1) copper flexible cable 2) copper armoured cable 3) Aluminium cable

1663


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1711


why single CT used in DOL starter power circuit?

2574


What are the differences between single phase and three phase?

2094


How to measure the Harmonic Distortion of UPS ie THD?

2411


how to produsing geretor power

2251


Do inductive loads have distorted current waveforms ?

1999


what is the difference between Central Battery System and UPS in applications and uses? and why UPS suitable for Computers and central battery for emergency lighting?

10371


draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it

2760


how to select the isolation tranformer for siemens 802dsl cnotroller

2120


CAN WE CALCULATE THE NEGATIVE SEQUENCE AND ZERO SEQUENCE REACTANCE OF A GENERATOR USING ONLY ITS RATED VOLTAGE, KW, PF AND SYNCHRONOUS REACTANCE??? IF YES, THEN HOW??

5701