Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how can we represne the analog signal and digital signal if
want to measure the speed and we have to use PLC

Answer Posted / guest

You are right Hmt,but you are giving the digital signal only
read the question carefully

Digital Signal :- for this purpose use zero speed controller
to measure the 0-1400RPM.
in this controller there is one delay & one instant contact
The proximity switch sense 0-200RPM speed gives signal to
Controller ,controller gives the instant relay contact to
PLC as Digital signal as Motor is Runing if motor reach to
the statable speed with the time period the controller give
the delay contact to PLC as digital signal.

Analog Signal:- For the purpose use encoder inside the motor
shaft with give conitious pulse with every roation in the
form of (4-20mA & 0-10v)with respective to )-1400RPM or
whatever speed we configure to PLC as Analog Signal

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the parameters of water ( Water quality )to be monitored in Centralised HVAC ( water cooler chillers )

2121


1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?

2050


why servomotor motor? where i apply for best output?

2089


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2525


what is the max. acceptable leakage current in 33kv bus bar

3074


The shot circuit in any winding of transformer result? Explain

1390


what is per unit calculation?looking for simple and strong explanation thk u

2947


HOW WE CHOOSE EARTH'S POTENTIAL AS ZERO V?

2114


Draw transformer phasor diagram.(full load,no load)

4223


WHAT IS FAULT CAPACITY OF HT MOTOR TERMINAL BLOCK? ANY BODY HAVE ANSWER PLZ....POST IT.

2247


what is meant by poly phase induction motor ? how its operating by single phase or three phase?

2211


critically criticize the application of ring main unit in power system

1503


Explain what is electric traction?

1188


How to calculate LT XLPE CABLE for 11 kv / 433 v , 1000 kva oil type transformer system?

2006


what is parellel power factor correction?

4496