Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why twisted pair of wires is used in instrumentation ?

Answer Posted / kavitha

twisted pair cables are very qualitative in nature as they
prevent electromagnetic interference from external sources
and crosstalk from external wires. They are majorly used in
telephone networks, data networks and cable shielding. Our
twisted pair cables are of two types, which are: Shielded
Twisted Pair Cables: These cables protect cable from
external electromagnetic interferences and are used with
token ring networks. Unshielded Twisted Pair Cables: These
are the unshielded twisted pair cables which are highly
flexible and long lasting in nature. Our cables are used in
many Ethernet networks and telephone systems

Is This Answer Correct ?    26 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the constant voltage unit?

1133


Gas equation

1896


sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com

2375


what is sliding spool valves?

2293


What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1962


Which type of diagphram use in costic line,DM water line,natural gas line,oil line?

3962


i want to find out iffco get test paper

13228


while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1969


please send the drdo exam paper

2431


when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??

2228


why we are using drum level control valve air to close?

2147


why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2792


can we create an interrupt in plc through scada?

2420


what is the criteria to decide conductor size of a cable ?

1929


defination of radial vibration?

2341