What are the various methods for effecive earthing in a
factory in a rocky terrain, where soil resistivity is
extraordinarily high? The usual method of 3 m deep earth
pits is not serving the purpose.
Answer Posted / ashish
If Earthing Resistance Value is more than minimum specified
value & one pit can not serving the you have to provide
Three to Four Earthing Pit Which are Interconnected
Together Making The Earthing Mat So The Total Effective
Value Will be Less.
| Is This Answer Correct ? | 15 Yes | 3 No |
Post New Answer View All Answers
While testing a ZCT what parameters have to check or measure?
What are the effects of adding a zero to a system?
Difference between Earthing Truck & Earthing trolly for HT panel
What is the difference between electronic regulator and ordinary rheostat regulator for fans?
what is the difference between "Rotary bypass isolation switch and Normal bypass switch" pls share indepth techs?
What is meant by rotor?
Why 11kv to be generated in generation station
Hi, Next week Iam appearing RRB exam for section engineer. So help me to get modal question papers for this position. Iam very thankful to you. Whether question will be fully techanical format or general form. Please give me a details regarding this exam.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What is Diff btw Fire Alarm & VESDA System???
Please explain, how to test vector group of tranformer(Delta y1) . Thank
we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor
What should be the height of basement according to NBCC code?
Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??
What are the main advantages of bode plot?