Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11

Answer Posted / raman jain

I am not convinced with the fact that due to form factor
1.11 generated voltages in India is multiples of 11 kV. If
it is so why we use 400 kV and not 440 kV , even we are
going for 765kV which is also not the multiple of 11.

Why only Indians consider the form factor for deciding the
generating voltage level? Why western countries are not
bothering about this form factor.

In my opinion it is just co-incidence.

Is This Answer Correct ?    97 Yes 31 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to decide the panel size like MDB ,SMDB PANEL SIZES

7286


my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.

1993


Why is it prefer to initiate circuit breaker failure by "86" lockout relay not by "94" tripping relay ?!

1748


The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason

2379


Hi, This is Laila. I am selected for syndicate bank interview. Could you please share your views and the questions asked if you have faced the interview My email id is laila_honey09@yahoo.com Please send as fast as u can.Thank You Thanks... Laila.

2052


whate is the meaning of balance/unbalance,in stabilizers type

2089


what is the total power generation in india?

2246


Readings of ER300P Trivector meter

6363


why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.

3023


STATE USE OF ARC RUNNERS & SPLITTERS ?

1868


WHAT IS THE DIFFERENCE BETWEEN AN ACB & mccb 7 WHAT IS THE CRITERIA WHEN TO USE WHICH OF THE TWO

2261


what are the dimensions for 200 kva transformer plinth (plateform),in which pcc m20 is used..

11589


i have gear oil pump with single phase motor.some time its motor starts running in reverse direction rather than forward direction...whats the reason behind this issue. 1- either capacitor is week? 2- or winding is week?

1333


how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.

1918


Why in 6 KV XLPE cable termination kit used and why not in 380 V xlpe cable same is not used

2574