In India,we use 230V,50HZ,where as many other countries use
110V,60HZ what r d advantages and disadvantages of each of
them?
Answer Posted / manikiran
High Frequiencies generate High Synchronous speeds and low
voltage means that low Ironlosses....Where as the High
voltage transfer more power with same loss in the line when
compared with a Low voltage line
Is This Answer Correct ? | 26 Yes | 7 No |
Post New Answer View All Answers
After synchronization with grid what is the demand value QKVAR and how we will maintain that?
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
what things to be considered when designing UPS
How to reduce the static electricity producing in solvent room? By P.D.Patil BioCon
Can any one know what are the symbols at the down (below) the analog ammeter??? there are 4 symbols which are they ?????
What do you mean by reach and reach the point of the relay?
can any one tell me about the Extra low voltage systems?From where we give supply to these type of systems??
In synchronous motor, how the field current is related to armature current..i know its inversely proportional..but concept wise...i was nt clear....pls help me...
HOW WE CHOOSE EARTH'S POTENTIAL AS ZERO V?
How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
What is systematic error?
in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????
What is “pu” in ee?
What is the Surge suppresor? Why using in a UDB's and How it works?