Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What does negative slip of an induction motor signify?

Answer Posted / trupti

slip=(Ns-N)/Ns
wh Ns - sync speed
N - actual speed of rotor.
generally whn IM is acting as motor,rotor speed is always
less than Ns,but if it is acting as gen(a prime mover moves
rotor),N bcms gr8er than Ns.
hence 4m formula we can c that s bcms -ve.
it implies rotor is running faster than stator field.

Is This Answer Correct ?    29 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the abbreviation of NGT panel

2084


Why slip ring ind. motor power consumption is low compare to induction motor .same 90 kw motor used same load output

1897


why transmission is only 3 phase and not 2 or 4 or poly phases

2185


hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...

2732


What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?

2327


What is the difference between rulling span and wind span of of an Over Head Transmission Line?

2385


What is vaccum currcuit breaker.define with cause and where be use it device?

1163


how many stairs have you climbed while you were coming

2231


How to determine stage of Automatic Power factor controlling Relay(Apfcr)?

2219


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2805


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2198


Please define ohm’s law for a.c (alternating current)?

1136


Sir, I have applied for the of Assistant.engineer of NPDCL. please send me all AP TRANSCO AND JENCO solved papers of previous exams . I requested send me the papers to my id as soon as possible (rajanikanth_peddi@yahoo.co.in) (This is very urgent) Thank You,

2949


what will happen if ac and dc supplies given

2191


why only exciting current is shown not primary current in transformer???

1913