Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHICH INSTRUMENT USED TO CALIBRATE CONTROL VALVE?

Answer Posted / ravi sankar

we can calibrate the control valve by using source meter
which is used to give 4 to 20 ma source to I/P , if any
error in the I/P ,we can adjust the zero or span of I/P.if
any error in the valve position ,adjust the zero or span in
the posisner of the control valve.

Is This Answer Correct ?    195 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)

2265


How to convert mmWc(mili meter water colam) to tph(ton per hour)?

981


Explain pH, Conductivity.

2161


in differential pressure transmitter,min&max pressure range for hp&lp

2004


how can i check vortex shedder bar it is ok? if there is ohms condition are shown correct?

2221


Turbidity analyzer working principle ?

1782


What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?

1065


what are the values of fuel flow rate in various places in boiler.

1726


Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system

1530


How will you calibrate PID controller? explain with example.

2435


what is the difference between scaler and vector drive

2181


how to calibrate steam control valve in steam turbine

3330


Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?

1933


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

2212


can we create an interrupt in plc through scada?

2377