TNS-00316: Ran out of data buffers in the pump
Answer / guest
Cause: The Interchange is resource limited by having too few
data buffers in the pump.
Action: If the problem persists (that is, there are a lot of
log messages), increase the number of pump buffers by
increasing the value of the parameter PUMP_BUFFERS in
INTCHG.ORA. Then shutdown and restart the Interchange to
make the changes take effect.