RMAN-06470: DEVICE TYPE is supported only when automatic
channels are used
Answer / guest
Cause: The DEVICE TYPE option was specified with a BACKUP,
RESTORE, RECOVER, DUPLICATE, CHANGE, VALIDATE, CROSSCHECK,
or DELETE EXPIRED command. This option is allowed only when
automatically allocated channels are used.
Action: Remove the DEVICE TYPE option and re-run the
command. Or Remove all ALLOCATE commands and re-run the
script so that channels are automatically allocated.
Please add more information about this Error
| Is This Answer Correct ? | 1 Yes | 0 No |