RMAN-06190: PL/SQL package string.string version string in
string database is not current
Answer / guest
Cause: RMAN detected an old version of the specified
package. RMAN will execute in backwards-compatible mode.
Action: No action is required, but certain features and
bug-fixes may not be available when RMAN runs in
backwards-compatible mode. If the database is CATALOG, then
you can use the UPGRADE CATALOG command to upgrade the
recovery catalog to the most current version. If the
database is TARGET or AUXILIARY, then you must either
upgrade the specified database or use an older version of
RMAN. The files that must be run to upgrade the target or
auxiliary database are dbmsrman.sql and prvtrman.plb.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
NNL-00022: error changing trace level from string to string, level change ignored
ORA-01953: command no longer valid, see ALTER USER
ORA-07614: $CHANGE_CLASS failed in retrieving the user's process label
ORA-02397: exceeded PRIVATE_SGA limit, you are being logged off
LFI-00008: SLTS's initializing/terminating mutex failed for string.
RMAN-06541: tablespace string will be included in future whole database backups
ORA-12485: new effective label not within effective clearance
ORA-13156: table to be registered string.string is not empty
ORA-32019: The parameter SPFILE cannot be updated in the server parameter file.
ORA-00403: %s (string) is not the same as other instances (string)
ORA-26517: materialized view control entry for 'string.string' was not found
PCC-00011: Already in a declare section at line number in file string