QSM-02174: the materialized view does not have a UNION ALL
marker column
Answer / guest
Cause: For a materialized view with UNION ALL to be fast
refreshable, it must have a UNION ALL marker column. This is
a constant column, at the same ordinal position in each
query block and must have distinct values in each query block.
Action: Add a UNION ALL marker column to each query block in
the UNION ALL query defining the materialized view.