PCC-00113: Value of DBMS option invalid with given value of
MODE option
Answer / guest
Cause: When MODE={ANSI14 | ANSI13}, DBMS=V7 was specified,
or when MODE=ANSI, DBMS=v6 was specified. These option
settings are incompatible. Note that the DBMS option was not
available before release 1.5 of the Oracle Precompilers.
Action: With DBMS=V7, instead of MODE={ANSI14 | ANSI13},
specify MODE={ANSI | ORACLE}. With DBMS=V6, instead of
MODE=ANSI, specify MODE={ANSI14 | ANSI13 | ORACLE}, but
MODE=ORACLE is recommended.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
ORA-24181: The type string does not exist
TNS-00281: Connection Manager: Forced Log output
RMAN-06438: error executing package DBMS_RCVMAN in string database
ORA-06902: CMX: cannot attach to cmx subsystem
ORA-19330: Type 'string'.'string' not installed. Please install the type before using the CREATE_DBURI operator
NZE-28802: invalid mode or data source in configuration file
ORA-38425: attribute set used for an index object may not be unassigned
ORA-13618: The value string is not a valid value for procedure argument string.
ORA-33460: (ESDREAD10) Discarding compiled code for workspace object because object workspace object is not in analytic workspace string.
ORA-23503: error occurred during IAS instantiation
ORA-27480: window "string" is currently open
NNL-01008: Outbound message contexts allocated: number