PCC-02101: Unable to open input file
Answer / guest
Cause: The precompiler could not open the input file. This
is the .pc file specified in the INAME=option. This means
that the file does not exist, that a directory was
incorrectly specified in the pathname, or that the person
running the precompiler does not have read permission for
the file. This message could also result from
operating-system errors. For example, an unmounted file
system or disk I/O errors, could trigger this error.
Action: Check that permission to read the file exists and
that the full pathname has been specified correctly. Check
for operating- system problems. See also the operating
system-specific Oracle documentation.
Please add more information about this Error
Is This Answer Correct ? | 0 Yes | 0 No |
ORA-12060: shape of prebuilt table does not match definition query
ORA-01150: cannot prevent writes - file string has online backup set
ORA-31035: Could not bind locked resource to path string/string
ORA-25287: Invalid value string, string should be non-negative
ORA-16750: Resource guard encountered errors while activating logical primary
ORA-01505: error in adding log files
RMAN-04032: using contents of file string
ORA-24758: not attached to the requested transaction
ORA-06955: Number of database servers exceed limit
SQL*Loader-00458: Comparison text ('string') of CONTINUEIF LAST must be non-whitespace
ORA-16099: internal error ORA-00600 occurred at standby database
ORA-25147: UNIFORM SIZE value greater than maximum extent size