PCC-02101: Unable to open input file
Answer / guest
Cause: The precompiler could not open the input file. This
is the .pc file specified in the INAME=option. This means
that the file does not exist, that a directory was
incorrectly specified in the pathname, or that the person
running the precompiler does not have read permission for
the file. This message could also result from
operating-system errors. For example, an unmounted file
system or disk I/O errors, could trigger this error.
Action: Check that permission to read the file exists and
that the full pathname has been specified correctly. Check
for operating- system problems. See also the operating
system-specific Oracle documentation.
Please add more information about this Error
Is This Answer Correct ? | 0 Yes | 0 No |