ORA-34276: (MXDCL33) (Precision, Scale) arguments can only
be used with a NUMBER variable or dimension.
Answer / guest
Cause: The user attempted to use NUMBER(Precision) or
NUMBER(Precision, Scale) as the dataype in a definition for
some object other than a DIMENSION or VARIABLE, such as a
FORMULA or PROGRAM. This error can also be produced in cases
where a NUMBER data type is not allowed at all.
Action: Use the NUMBER type without specifying a precision
or scale. If a NUMBER data type is not allowed at all, this
fix will only change the exception message to something more
specific.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |