ORA-19643: datafile string: incremental-start SCN is too recent
Answer / guest
Cause: The incremental-start SCN which was specified when
starting an incremental datafile backup is greater than the
datafile checkpoint SCN, which could cause some blocks to be
missed.
Action: Specify a smaller incremental-start SCN.