ORA-01671: controlfile is a backup, cannot make a standby
controlfile
Answer / guest
Cause: The currently mounted controlfile is a backup
controlfile, and attempting to create a controlfile for a
standby database.
Action: Complete any needed recovery and open the database
with the resetlogs option.