ORA-16805: Change of LogXptMode property violates overall
protection mode.
Answer / guest
Cause: The standby database resource guard rejected the
attempt to change the LogXptMode configuration property for
the standby database. The rejection was necessary to avoid
violating the overall protection mode for the configuration.
Action: If the LogXptMode configuration property must be
changed for the specified standby database, first downgrade
the overall protection mode for the broker configuration.
After that operation has completed, you will be able to
change the LogXptMode configuration property for the standby
database.