Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

ORP sensor working principle?

Tata Steel Limited,

2008

what is the principal of operatio of dc motor

1 2308

How does your previous experience relate to the job you are applying for ?

2014

I am applied 100 % pressure on to the air to open control valve,but the valve is not fully closed..and 10-15% is open the valve. how to calibrate the control valve?

OPaL,

3 4305

how to turbine speed measurement?

Jindal Steel and Power,

1582

I have a problem with a valve (air to close). When it is fully closed and try to open 1% it doesn't responce till 3% open suddenly more than 3% then back to 3%. I tried to tune positioner then removed it, the problem still exist. Any idea

3 3765

in yokogawa prosef rd safety PLC how to data send frome local SCS to other SCS and other FCS

2 3260

dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

CPL,

1890

In apron feeder how TPH is calculated?

Lafarge,

1726

Flame scanner

1 2425

why fuse block is not used for AI signal?

1891

how can i calibrate the temperatuture gauge used by temperature bath(dry block) i mean step by step procedure?

Texas,

1674

how can i calibrate a smart temperature transmitter used by druck 720 process calibrator?

Texas,

1588

what is the calibration procedure for magnetic flow meter @ onsite

1653

Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .

1703


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

What is force balance principle? State some of its’ advantages.

1175


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1658


If P will increase then what will happen with PID?

6061


we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks

2175


How is PH sensor works ?

1964


Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?

2462


What is ultrasonic flowmeter?

1110


what is dc moter.

2227


Gas equation

1850


Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram

3109


What is compensation for flow ? Why we use compensation ? What are the factors of different compensation ? We not use then what problems may happen ?

1977


How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.

2140


what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.

2093


Why thermo wells are used? What materials are used in thermo wells?

1119


What are advantages and disadvantage of the ac supply load cell?

1051