Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

RR Electronics Communications Interview Questions
Questions Answers Views Company eMail

pulse period of two signals are 5ns,10ns .which will give high frequncy component?

4 8287

Post New RR Electronics Communications Interview Questions




Un-Answered Questions

Can anyone suggest me how to write test cases for an application developed in image processing domain

1659


what is the size of ht cable of 33kv ht line and transformers ratings are 1 Mva and 5mva.please send formula also.

989


how to measure method execution time in java

93


Can you use windows 7 without a product key?

431


How do I learn Python machine learning?

107






How much space does ubuntu take?

379


what is the difference between seton lr and retrn?

1270


what is the chemical component of eggplant that stimulates the blood glucose level?

1553


What is depreciation key? : fi- asset accounting

699


What is inline function in c#?

507


How long does the light from sun take to reach us?

501


Is spark sql similar to drill?

5


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

1958


What is the high series capacitance winding on high voltage power transformer ?

1606


What does the 'ceci:cics' transactions do?

632