Engineering Interview Questions
Questions Answers Views Company eMail

How to Calibrate Vortex Flow transmitter in field

769

How to Calibrate Level Troll in field

767

How to Calibrate Interface Level Troll in field

780

How to Calibrate Flammable gas detector in field

722

How to Calibrate Coriolis Flow transmitter in field

752

How to Calibrate Mass Flow transmitter in field

768

How to Calibrate Level Switch in field

790

How to Calibrate Temperature Switch in field

801

How to Calibrate Flow Switch in field

764

How to Calibrate Vibration Probe (Axial, Redial) in field

713

If an ID Fan is designed for a suction pressure of - 250 mm wg and discharge pressure of +150 mm wg, and it is installed in a system where the required system resistance at suction is only -50 mm wg, will the ID Fan be able to produce a discharge pressure of +350 mm wg?

1 1445

what is the productivity in aluminium shuttering per day

1575

Interview questions for ITC Ltd for ECE stream

1377

During FEED, you will have all the information with regards to cable. How will you calculate the MTO for MV and LV Cables? what are your considerations?

2034

Why need 3phase machine double earthing?

1334


Un-Answered Questions { Engineering }

What happens when ac supply is given as excitation voltage instead of dc supply

3133


Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?

1317


I have energy meter for educational project having 0.5s class but my friend need 0.2s class meter , which one is good for that purpose and what is the actual difference of that two classes , need very easy example also.??

990


Tell me all plants load factors i.e which plant operating on which load?

1553


what kind of questions generally asked for ME admission, (specially in RGPV).

1567






What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

975


Calibration of controller (pneumatic)

1516


what is draft and draft loss?in a boiler,how is draft created?

1874


Which pipes are used for steam lines?

597


What medical aid is NOT allowed to carry with you on air-craft?

1143


why T/F winding temp measurement cts are odd secondary current ie,109A/1.2A/1.4A?

1376


What are the characteristics of negative feedback?

611


Explain the fashion accessories?

5


Did elevation affect weight?

653


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1739