If an ID Fan is designed for a suction pressure of - 250 mm wg and discharge pressure of +150 mm wg, and it is installed in a system where the required system resistance at suction is only -50 mm wg, will the ID Fan be able to produce a discharge pressure of +350 mm wg?
Answer / saumabha bagchi
Theoretically yes, as the differential pressure is -400 mm wg [-250 - (+150)] or [-50-(+350)] in either case. But is this true in practice ?
| Is This Answer Correct ? | 0 Yes | 0 No |
relation of BSP and BSW threads in inches
can any1 suggest me the books for placement papers.
• Do you consider yourself a leader?
1 Answers Petro Star Mount, Tech Mahindra,
What is a brake horse power?
WHY DO DEAD BODIES SAIL ON WATER WHERE AS A HUMAN BEING GET DROWNED?
How is propeller fitted in shaft?
What is the importance of tolerance in engineering?
give the function of thermostat
I am a technical graduate with 2 years of experience in automobile industry. i want to prepare for air force technical level examination. will u pls tell me what is the syllabus or do u have some model question papers???
what can be the technical questions for the post of a design engineer?
What are sleeve and cotter joint?
what is the difference between 1st angle and 3rd angle projection?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)