Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

State 5 different method of level measurements.

SRACO,

3 6862

what is the essential difference between DIODE and SCR in term of application.

ADMA OPCO,

2 6039

In turbine, what does term CDP, NI, NH, HSSOC, means

ADMA OPCO,

2777

An equipment is certified for EEX, IA, IIC, T6, what do you under stand by this.

ADMA OPCO,

3 7695

I HAVE PRESSURE TRANSMITTER WITH TWO WIRES 24 VOLTS SUPPLY.IF TRANSMITTER WILL GIVE SIGNAL TO THE DCS WHAT HAPPEN TO THE 24 VOLTS POWER SUPPLY IT WILL DROP OR REMAIN TO 24 VOLTS POWER SUPPLY.

3 7937

what is sequence table in DCS . make a logic in sequence table for tripping of ID fan in Boiler(in YOKOGAWA CS 3000 DCS).

Yokogawa,

1 7536

Dear all... I have 1 0-400 duplex type RTD, I connected the A side to the temperature indicator and B side to the PLC panel, but when I have observed then found that The PLC side temp has the variation. and it was distub to other RTD temp also. so what can I do.

1 4499

Dear all... I have 1 0-400 duplex type RTD, I connected the A side to the temperature indicator and B side to the PLC panel, but when I have observed then found that The PLC side temp has the variation. and it was distub to other RTD temp also. so what can I do.pls help me

Worley Parsons,

1 5048

Can we used Condensate Pot on flow transmitter which is using on liquid having sluge and DP transmitter is in pit and below the process line,Can we used Condensate pot for accamulate the Sluge?

1 5821

What properties or parameters to be taken into consideration for protection while selection of Dcs controller.

JPL,

1 4329

What is the difference between ROM & RAM .

Sabic, SPIC,

1 5588

Can we use a 10000 Lph Flow Transmitter in 100 LPH flow line to get 20mA O/P by adjusting SPAN ?

1 4694

in differential pressure transmitter,min&max pressure range for hp&lp

2010

What is the difference between EPROM & EEPROM.

Sabic,

1 9345

What is scale factor of proximitor & unit of the viabration.

Sabic,

2 6089


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?

1889


Reason for capillary type dp level transmitter fluctuation

1986


how many pulses are required by a ac induction servo motor of 4 poles with 50 Hz frequency to rotate by 1 degree?

2120


What is Alpha & Beta fctors related to Orifice Plate & its relation with flow?

3379


How to interfacing microcontroller with a DC motor

2064


wich is coming the first HAZOP OR SIL

2763


There are two chlorination tonners both are connected to two pressure swithes and the pressure switch is connected to SOV which operates the valve to changeover the tonner selection i.e if pressure one tonner goes low the other tonner should come in line if it is inautomatic selection design a circuit using relays ?

1967


Why mmwc unit is used?

1201


how can use ram

2062


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

2197


PLEASE PROVIDE SAMPLES OF CHEVRON SKILL TESTS

3901


Explain the mechanism behind the turbine meter.

1122


A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.

1362


why fuse block is not used for AI signal?

1898


Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection

2020