Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

Siemens Interview Questions
Questions Answers Views Company eMail

What is the journal entry for goods sold to Mr A in 1 month credit of rs 5000. and also pass entry for non repayment of money after 1 month by Mr A. (What entry will come for this?)

3 13899

Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2519

what sq.mm copper pvc wire need for ac load current 25amps for 230v ?

4 7967

What is purpose to use relay after digital output module? Why normally we don't use relay for digital input module?

3 8501

how to calibrate load cell

2843

is earthing is necessary if we use armoured cable

1 5794

What are d uses of a diode . What is diode equation . And what is its use

2 7394

what is mean by dry frequency

2473

how is the testing of an REF relay? what are the test REF circuit having?

2011

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2154

Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?

1988

What is mean by spike arrester(Voltage Operated)

2074

I have AC automatic voltage regulator 15KVA What output currant?

3 5639

Can we calibrate an actuator?

5 12643

why transmission voltage is 230kv and not 220kv which is a multiple of 11

1 6463

Post New Siemens Interview Questions


Siemens Interview Questions


Un-Answered Questions

What is the difference between the data frame and a matrix in R?

88


integration test cases for mouse and keyboard

3735


Can you write a code to select all links inside the paragraph?

858


How to change start and end symbols used for angularjs expressions?

810


How secure is apache web server linux?

1113


Specify key disadvantages of android?

927


Tell me which data types is not supported by the peoplecode programming environment?

849


Is it possible to link the sharepoint to an external data source?

796


Why is python not fully object oriented?

991


Explain the new features 3.5 framework against with the tool?

963


Why is your CGPA not higher?

1385


How can the size of statusbar be increased proportionally?

407


Is hibernate session thread safe?

445


Which is better shopify or wordpress?

180


What was the most difficult deal you had to close?

1005