Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

Siemens Interview Questions
Questions Answers Views Company eMail

What is the journal entry for goods sold to Mr A in 1 month credit of rs 5000. and also pass entry for non repayment of money after 1 month by Mr A. (What entry will come for this?)

3 12600

Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2031

what sq.mm copper pvc wire need for ac load current 25amps for 230v ?

4 6547

What is purpose to use relay after digital output module? Why normally we don't use relay for digital input module?

3 7096

how to calibrate load cell

2328

is earthing is necessary if we use armoured cable

1 4919

What are d uses of a diode . What is diode equation . And what is its use

2 6215

what is mean by dry frequency

1945

how is the testing of an REF relay? what are the test REF circuit having?

1465

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1671

Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?

1520

What is mean by spike arrester(Voltage Operated)

1616

I have AC automatic voltage regulator 15KVA What output currant?

3 4494

Can we calibrate an actuator?

5 10882

why transmission voltage is 230kv and not 220kv which is a multiple of 11

1 5508

Post New Siemens Interview Questions


Siemens Interview Questions


Un-Answered Questions

What is wsdl used for?

473


is the meter head is same as back pressure?

1612


How do you truncate a file using node.js?

250


Is there a switch..case statement in python?

477


Pl send the model question paper of mahagenco account officer post

2259






What is account payee cheque? Expand ctc cheque?

726


why do we have spikes enough to burn electronic boards, when generators are not grounded

1330


What is object service? : Entity framework

635


Explain directives in angular js

442


What does sorted do in python?

486


Define grading?

1


Given, T1=600C, constant temperature of wall 800 , length of wit exchanger L=3m, dia=25 mm, Cp=14.91 KJ/kg.K, density ρ=914 kg/m3,mean velocity vm= 2 m/s, film heat transfer coefficient hf=72 Kcal/h.m2.K, what is the outlet temperature?

1615


Explain the steps involved in submitting the App to App-Store in iOS operating system?

498


How to invoke batch apex job (or) how to execute the batch apex job programatically?

206


What’s block for?

191