Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

explain why direct on line starting toque and current may
not be acceptable

Answer Posted / vdw

If a system needs high starting torque then corresponding motor will draw very high current, in such a case it may get overload or probably causes electrical flash which is not acceptable. The remedy for this is to use star delta starter for the motor so initial current drawn by motor will be within safe conditions of motor.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

explain how the third harmonic content of the magnetising current affects transformer design

3295


How to calculate power press toneage

2075


what is restricted earth fault explain in details

2058


why do you consider yourself a suitable candidate for this position

7461


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1717


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1707


Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.

2422


Why superheated are started before I'd and rd fan?

2192


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1008


LAPT working in alternator / generator

3643


procedure of how to generate power in solar plant.

1961


What is LB-SR.

3020


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2444


How We Calibrate the vaccum transmitter?

1979


By any way can we increase the B check hours from 300 to 500

2212