Is your generator is automated or manual if so do you know
the circuits?

Answer Posted / mani0786

mannully start genset start manually & wwhen it come with a amf or ats panel it said auto genset well sir your question is out my mind but so i give it a simple sot

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the importance of earthing?

669


Sate maximum power transfer theorem?

701


what are factors to be consider in electrical installation like load factor,diversity factor .....

1366


tell me about roaster switch .& what is the function in transmission & distribution?

2172


how we do Vector group ,magnetic balance and tap changer test in Transformer?

2035






Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1661


explain types of electric welding and its applications

1208


How equivalent impedance is calculated in thevenin theorem?

638


how can decide the current rating of oltc

1866


What is shunt voltage and u v voltage witch one best

1301


Hi everyone. Some Generators uses 3-Pole breakers with extra contactors for Neutral. Some uses 4-Pole. Why so? What is the idea behind this? Thanks in advance for the solution. Kr.

1618


how to calculate the settings for shaft ct protn in hydro generators

1506


What id difference between power and energy?

664


For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?

1473


I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?

1784