Convert a pressure, level, flow, or temperature process
variable value into the appropriate pneumatic or electrical
value given different types of instruments.
Answer Posted / sattar
pressure=(use bellows to get pneumatic output or use pirani
gauge for electrical output).
level=(use float type sensor )
flow= (use electromagnetic flow meter)
temperature=(use RTD or thermocouple)
Is This Answer Correct ? | 23 Yes | 0 No |
Post New Answer View All Answers
Why the ammonia and Nitric Acid level indicators is with millimeter ? and What is the conversion form millimeters that level indicator indicate to weight ?
Isometric drawings are generated during _________________ phase of a project
why orfice is not used for main steam flow calculation
Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.
How to fix back the valve actuator stem
Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system
Pl send the model question paper of mahagenco account officer post
Tr. Wiring for calibration.
what is moisture probe? What are there types? What is there working principle and how they works? guys this is one of technical question I had ask in interview. If you know its answer please let me know. The interviewers were more interested in microwave moisture probe, so if you find its any link please just forward me on my mail id.avinash1200@gmail.com Thanks in advance.
Hi i m B.E. In elect. & comm. I m workin in bio mass plant from 6 mnths as inst. Engg. but now i m in dept. Of operation as shift engg...which is best operation or inst. 4 me? M confusd..plz help and reply me..
the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)
how to turbine speed measurement?
the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove
What is voltage regulator?
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?