Is your generator is automated or manual if so do you know
the circuits?
Answer Posted / yuvi
Honestly, this question does not make any sense. However, I
will try to answer to the best of my understanding.
1) I don’t have a generator.
2) Difference between manual and automated generator is
that in a manual start generator, we will have to manually
start it. In an automatic start generator, a circuit senses
that the power has failed and starts the generator
automatically using a small battery powered motor similar
to the ones that start your car. The sensing circuit can be
of a wide variety. It can be a magnetic relay or an
electronic circuit depending on the area of application.
| Is This Answer Correct ? | 14 Yes | 1 No |
Post New Answer View All Answers
What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?
why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)
why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.
how you configure motorvision relay (L&T make)from DCS
How to check 11000/1.732 to 110/1.732 Potentila transformer (PT)?
what is the stear deltaprinceple?
which is better to use svc or synchronous condenser why ?
as a electrical student why should i hire you?
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
what is the minimum pay scale for electrical engineer (building construction)in kuwait? plz revert back with yrs of experience & pay scale respectively.
The Q-facr o of a coil given as wL/R. what will be shape of Q versus frequency graph.
What is the difference between circuit breaker and isolator
how to calculate kvar in Akiva
why do we use 25kv supply for traction purpose?
How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).