define IDMT relay?

Answer Posted / anil

it is a over current protection relay

Is This Answer Correct ?    31 Yes 80 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will happen if the voltage in my house drops from 220V to any lower voltage?

1667


any one can explain the stages of a knee point which is taken during ct magnetising curve.

1328


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1668


What are the basic components of the feedback control system?

624


why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?

1466






what is RFID? thire application;

1542


how ct burden,magnetising current,ratio and knee point voltage are related & derived

1773


LT cable fault chaecking equipment and to find out the distance at what distence it failure . Name and where it is available?

1686


How would your past experience translate into success in this job?

6466


Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?

1487


What is the name of the winding to which supply is given?

705


What is order of the system?

719


what is acceptable leakage current for 33kv cable while doing high voltage test for cable? how to calaulate the leakage current for 33kv or any rated cable?

3465


we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain

1733


what is the safety points of vaccum circuit breaker.

1646