Where is the pressure reduce valve in the power plant

Answers were Sorted based on User's Feedback



Where is the pressure reduce valve in the power plant..

Answer / vks

IN PRDS LINE

Is This Answer Correct ?    11 Yes 0 No

Where is the pressure reduce valve in the power plant..

Answer / krishnamoorthy

Ejector & prds line

Is This Answer Correct ?    4 Yes 0 No

Where is the pressure reduce valve in the power plant..

Answer / vks

In prds line

Is This Answer Correct ?    2 Yes 0 No

Where is the pressure reduce valve in the power plant..

Answer / hassan

in HP bypass and LP bypass for steam turbine

Is This Answer Correct ?    2 Yes 0 No

Where is the pressure reduce valve in the power plant..

Answer / sudhakar upadhyay

Mssv or startup vent

Is This Answer Correct ?    1 Yes 8 No

Where is the pressure reduce valve in the power plant..

Answer / sudhakar upadhyay

Mssv is also known as pressure reduce valve

Is This Answer Correct ?    1 Yes 8 No

Post New Answer

More Power Plant Engineering Interview Questions

why drum level falls when one of the running coal elevations tripped?

3 Answers   APGenco,


what is IR in differential test on motor?

2 Answers   Adani, Adani Power,


what is the perfect location for furnace draft transmitter in AFBC boiler?

1 Answers  


Our 8mw steam turbine (condensing cum extraction) exhaust steam temperature is high even after taken it in hogger why

1 Answers   Bombay Rayon Fashions,


Need of oxygen dosing in super critical powerplants?

5 Answers  






what is voltage transformer explain in details

5 Answers   Khulna Power, NCC, Reliance Power,


how to differentiate between "ALL fuel lost" and "All Flame Lost" in Boiler MFT condition?

1 Answers  


What is MFT and when it is acted.

2 Answers   HPCL,


thermal power plants in steam using inlet of turbine.inlet of turbine pressure and flow is same as boiler feedpump why not use direct to turbine?

6 Answers   IBPIL, JSW,


What are the special criteria under which FD fans are switched off during MFT.

1 Answers  


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

0 Answers  


Difference between islanding and house load operation.

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)