What is the need of black rock stones under the transformer
yard?

Answers were Sorted based on User's Feedback



What is the need of black rock stones under the transformer yard?..

Answer / ankush

it is used to prevent the growth of trees (any type of ghas
or long trees) so that it will not cause any sort of
shortcircuiting.

Is This Answer Correct ?    8 Yes 2 No

What is the need of black rock stones under the transformer yard?..

Answer / satyendra jain

it absorb leaked transformer oil ,huming, and
prevents growing of plants and increases
point resistance also

Is This Answer Correct ?    7 Yes 1 No

What is the need of black rock stones under the transformer yard?..

Answer / 3nath

resistance is inversely proportional to area so using stones we are dividing area so automatically resistance will increase
so it will helps to prevent shocks in abnormal conditions

Is This Answer Correct ?    5 Yes 3 No

What is the need of black rock stones under the transformer yard?..

Answer / hkrish.eee

weather control

Is This Answer Correct ?    2 Yes 0 No

What is the need of black rock stones under the transformer yard?..

Answer / srinivasa rao talasila

It is used to prevent the growing trees and as well as any
snakes r lizards.

Actually because of this rock stones these animals are
unable to walk on stones.

Thats why we are using 2.5mts to 3 mts of surrounding of
the equipment r substation

Is This Answer Correct ?    2 Yes 4 No

Post New Answer

More Electrical Engineering Interview Questions

WHAT IS THE USE OF EARTH SWITCHES?

3 Answers   L&T,


what is the size of trasmission conducatar

2 Answers   TCS,


why we test the core balance of the transformer?

1 Answers  


what is the first step of dg shycroning ?

2 Answers   ABB,


A circuit breaker is a

9 Answers  






What is the difference between Neutral And Earth ?

2 Answers   Ambuja, Reliance,


I'm looking for a softcopy manual set for a Credence ASL- 3000. Anyone know where I can get it?

0 Answers  


what is the size of ht cable of 33kv ht line and transformers ratings are 2.5mva and 5.5mva.please send formula also.

1 Answers  


A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.

0 Answers  


Why cables and busbar both needed in LT Panels?

0 Answers  


why the generator operating along with the infinte bus bar should never be under_excited?

1 Answers  


difference between the earth mat and earth grid?

3 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)