Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

Process Control Technologies Interview Questions
Questions Answers Views Company eMail

The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?

1847

If a normal magnetic type flow transmitter that can measure flow, temperature and show this parameters on field, is it possible by any means to get this (flow and temperature) parameters info. On dcs? And if yes then with HART, FO communication or any other communication system?

1 1870

If a flow transmitter (magnetic type FT) that can measure flow and temperature, then why in some industries people use flow transmitter and temperature transmitter in the same line 1 after another? Even after 1 single flow FT is capable of measuring flow as well as temperature.

1 3992

I have installed a RTD whose length is 2250mm(RTD stem length), but it's upper 200 -250mm is out of the reactor, and this upper 200mm stem is surrounded by atmospheric temp. And the lower portion i.e. 2000mm is in contact with the measuring fluid, then does the final measuring temp. Gonna change as the upper 200mm RTD stem is out of reactor?

1 2037

How does a single acting, spring return ball valve actually work? Does it require continuous air supply? 

1683

In a ball valve which require 24v dc supply to operate, whose solenoid valve doesn't have any + or - indication, how can we make wiring connectionto solenoid valve?

1 3521

What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?

2636

Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

1722

Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions? 

1726

What is shielding effect?

1762

What is heating effect?

1886

Why is the length of cable layyed from RTD to temp. Transmitter should be minimum? Why does heating effect takes place in their?

1 5450

Why do we use triad cable for RTD to Temp.transmitter connection? Why we don't use 3 core cable?

1 13801

What are continuances of connecting earthing and shield of branch cables (instrument to Junction box), at the same earthing pot provided on JB? Is it ok, or may produce some problem? 

2018

Why do we have earthing cable in branch cable and shield in the same cable?

2153

Post New Process Control Technologies Interview Questions


Process Control Technologies Interview Questions


Un-Answered Questions

How do I enable activex on my mac safari?

440


type of sale and purchase tax?

1488


Describe the dimensions of the risk in qa?

603


How does xaml relate to registries (uddi)? : xaml

582


Can anyone have SAP-CO module ppt for begineers?

4518






What is repository manager?

538


What is the target set plan for distibutor...?

1589


When will the current screen processing terminates?

553


Does weight affect how far you jump?

573


Mention different types of messages available in JMS API?

466


Is php a backend?

539


Are data mart and dwh normalized or denormalized? Do both of them exist in the same tier?

591


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

362


What are the different ado.net namespaces are available in .net?

498


What is the definition of logical functions?

308