Synchrounous motor is three phase motor,but its not self
starting .why?
Answer Posted / ashli
synchronous motor stator has 3 ph winding n rotor s suplied
by a dc suply to form a north n south pole..supose two
magnets are aligned axialy. now rotate one of them slowly.
the other one also starts rotating with dat. thatz how the
working of syn motor can be xplained in a very simple way.
if we rotate the magnet fastly the other one cant move with
that much speed becoz of its inertia. when 3 phase suply s
given to the stator winding, a rotating magnetic field is
created with syn speed. but the rotor cant rotate. so at
first the rotor s rotated by some external means to the syn
speed n then give suply to the stator.so that the rotor
continues to rotate with syn speed
Is This Answer Correct ? | 79 Yes | 12 No |
Post New Answer View All Answers
33kv substation lay out details & line to line & line to earth measurements
how to compute kvar in substation feeder to improve power factor and sending voltage
What are the causes of having an rmu explode after installation? And how do u treat the bushings of an rmu?
what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.
upto how many load can v connect to stabilizer which is used for tv
What is the height of DA, DAL, DB, DC & DDE tower?
Why hydropower is called renewable source of energy?
Give atleast 20 alternating current apparatus and devices.
I WANT YHE TECHNICAL AND ELECTRICAL SPECIFICATIONS OF 2x4MW 11KV 2x10MW 11KV 2x25MW 11KV 2x100MW 11KV HYDEL POWER PLANT i.e PROTECTION SYSTEM,MONITORING,CONTROL SYSTEM,GENERATION,SYNCHRONISATION,METERING PLEASE SEND THE DETAILS TO MY MAIL ID SPRAVEEN_222@YAHOO.CO.IN
Why strting torqe high in inducation motor?
which model T or pie model is prefarable in power syatem
What is shutdown of electrical sub station?
1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
how to design the heater in temperature control unit to heat 50KL of water?