Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are using polystyrene film for calibration of I.R
spectroscopy?

Answer Posted / k ramesh naidu

polystyrene film having the all functional groups in the entire range of IR region. Because it consists of all carbon linkages related to all kind of groups.

Is This Answer Correct ?    16 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2874


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

721


If vendor having more imp than monograph then how to proceed? and how to set spec?

940


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1863


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

2739


why lactose has less charges when packed in steel containers when compared with packing of lactose in polyamide material?

2312


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

2727


how require to select dissolution media? what is discrimination?

801


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1609


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3188


What is the diffrence in japan mkt requirement in analytical method validation over US?

732


Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18

1926


why we use a particular hplc column for a particular compound give reasons?please

2756


what is classification of elemental impurities? what is risk assement in elemental impurities?

762


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9810