explain in detail HV & LV bushing connection in power
transformer (110 / 11 kv 16 MVA)

Answer Posted / satheesh k

HV side bushing connection is only 3 terminals R,Y, B. In
LV side 4 terminals are there R, Y, B, N. Neutral is
grounded in station transformers. But in distribution
transformers the neutral is not grounded in secondary and
is extended to commercial use.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOW WORK HEAT PLATE EXCHANGER

1534


What is dc current source?

739


why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.

1666


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1414


How many types of instrument cables are there?

640






How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?

670


what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value

1665


What is the difference in calculating size of AC cables compared to calculating size of DC Cables? Usually DC Cables are larger than AC Cables although they have the same ampacity. Why is it?

1538


he compression ratio for a petrol engine generally lies between

715


What is DTR erection?

3608


help me with the question that might be ask on the interview for technical position

1823


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1439


What is Diff btw Fire Alarm & VESDA System???

1950


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

1472


Why temperature rise is conducted in bus bars and isolators?

775