what is the defenation of efficiency in the high pressor
boiler? what is the formila of efficiency in the high
pressor boiler?

Answer Posted / m.sindhu pandi

BOILER EFFICIENCY:Ratio between heat output and heat input,
it's called boiler efficiency.



FORMULA FOR BOILER
EFFICIENCY:
Q*(H-h)/q*GCV

Q : Quantity of steam (kg/hr)
q : quantity of coal consumption(kg/hr)
H : Enthalpy of steam(Kcal/hr)
h : Enthalpy of fead water(Kcal/hr)
GCV : Gross calorific value of coal

Is This Answer Correct ?    42 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job

2077


LAPT working in alternator / generator

2561


can dp type level transmitter work in under vaccum condition

1547


what is the trip circuit supervision in an electrical meaning?

1450


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1439






Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

2991


why airtel use + 24 volts and other operators use -48 volt

2113


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1241


How We Calibrate the vaccum transmitter?

1474


By any way can we increase the B check hours from 300 to 500

1701


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

1486


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1203


Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.

1890


can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1284


How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.

1830