Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What impact analysis required for out of calibration and
how to proceed

Answer Posted / pranav

IN CASE OF OUT OF CALIBRATION AN EXTERNAL AGENCY WILL
CALIBRATE THE INSTRUMENT

Is This Answer Correct ?    2 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9810


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1982


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1875


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1609


Is it nessesary all multimedia dissolution require descriminatory?

814


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2693


Tell me about analytical method validation in QC

6192


in api coa contains only process impurities and in product coa contains degradation impurities?

708


Difference between hlaf and rlaf

2121


How much is the standard area for glc analysis

2295


how much mass should be there in volumetric flask while in preparation of sample for assay? 

2589


if you get peak in blank then what require to do?

984


what is diffrence between specificity and selecivity?

798


how many types of balance calibration test?

2314


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2874