How can we decide the fualt levels of sub-stations?
Answer Posted / akarsh mittal
fault level is given by
I(short circuit)= I(rated)/% impedance
Hence fault level is determined by percentage impedance of a line
| Is This Answer Correct ? | 13 Yes | 0 No |
Post New Answer View All Answers
Dear all, i completed M.E(Power Electronics & Drives) 2011 passed out having 78% so i need job in core side but i don't know how can i receive the calls from electrical companies and i uploaded my CV in naukri, times jobs etc.. In that iam not recieved any mails from good companies so give me best procedure plzzzzzzzzzzzzzzzzzzzzzzzz..... Thanks, K.Linga Reddy Email-id:-lingareddykmthm@gmail.com Ph no:-08015402078
63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate?
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
What are the advantages of instrument transformer?
What is the diff. between single compression and double compression gland
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
can you send me the placement papers of electrical engg. from companis like NTPC,DRDO,IOCL,HPCL,BPCL etc.?If,plz send as soon as possible.Thanks.
tan delta equation test on alternators
Explain The Application Of Storage Batteries?
What is the problem of internal failure in ship engine telegraph system norcontrol?
Hello Guys !! i want to rrb section engineer electrical(signal) previous model papers? any body help me?
how many single tension hardware are required on a double circuit transmission tower?
what is upper impedance and lower impedance of a distance relay
what is th basic difference between a d latch time line and a d flip flop time line???
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?