Answer Posted / chinmay
Hook-ups are basically of two types Process Hook-Ups and
Pneumatic Hook-Ups. hook ups give complete information
required for installation of a particular instruments which
indicates cable entries, support details, connection sizes.
It clearly defines the instrumentation scope for
installation and helps in identifying the materials and
accesories required during installation
Process Hook-Ups covers all field instruments installed on
pipelines/vessels and other process equipments and
Pneumatic Hook-ups covers all instruments which require
instrument air to operate
Is This Answer Correct ? | 13 Yes | 0 No |
Post New Answer View All Answers
what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.
How to calibrate Toxic gas detector?
Difference between dcs and plc including date processing and architecture.
Hi,can anyone help me out with PhD programs related to Instrumentation field?I have a degree in electronic Instrumentation?
How to calibrate the flow transmitter
How to control flow variations in magnetic flow maters..... When i will provide proper earthing?
What happen if I install my pressure transmitter below the elevation of pipe in natural gas service?
plz you help about Que paper of mahagenco previous your,any model paper relad to it{maharastra power genration}
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.
Which type of diagphram use in costic line,DM water line,natural gas line,oil line?
In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.
How signals can be taken through modbus?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
Galvanizing.