micromotion flow meter used for

Answer Posted / abdelrahman

I

Is mass flowmeter from EMERSON company and it used for
custody transfer application as it's accurate.
and u can get volume/density and totalizer.
working on the principle of Coriollis theory:
(when amass flows through a vibrating pipe coriollis force
are generated which will bend and twist the pipe these very
small pipe deformations are measured by optimally mounted
sensors and electronically evaluated.
because the measured phase shift of the sensor signal is
proportional to the mass flowmeter.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the types of control valves available

1537


Define cryogenic?

726


Actual using of tube bender to bend 2 opposite 90 deg at correct measurement center to center of tubing.

1501


What is the difference between ff transmitter and non ff transmitter

1979


what is SIL 1 2 3

1552






how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5231


How can i copy program (parameter) from mm440 (V.F.D.) by using BOP?

2290


Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows

1653


WHAT IS THE DIFF. BETWEEN SKIN TEMPERATURE AND PASSES TEMPERATURE..?

2088


Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer

4178


Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?

1535


dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

1411


Turbidity analyzer working principle ?

1338


what is the difference between active & reactive power?

1673


how to calibrate load cell

2326