How can we measure the level of a closed system like drum

Answer Posted / haridass

We can measure the level of the closed tank using
Differential pressure measurement system, or
ultrasonic level measurement, or
using displacer level measurement system, etc.

Is This Answer Correct ?    10 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon

1711


what effects a surging can produce in the compressor

1483


installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,

1680


you must show the examples application and give at least 4 types of transducer/sensors that can minimize the failure during the manufacturing of the resistors.

2849


How to Calibrate Ultrasonic flow Transmitter in Field

806






A length of steel pipe is used to carry sea water to a desalination plant. An adequate corrosion allowance must be specified and indicated in the piping specification, which affects the _________________________ of the pipe

1796


Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...

1844


I have got a call of IOCL interview for projects having 2yrs experience. What sort of questions should I expect in the interview?

1703


how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5233


How will you calibrate PID controller? explain with example.

1983


what is easiest way to read STL language in PLC?

2676


how to calibrate steam control valve in steam turbine

2831


Can anybody tell me how to select the size of earthing cable for DCS & PLC system.Please tell me any relevant answer here or mail it to me.

1702


while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1357


A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer

1908