what is the difference between RS 232,RS 485,RS 422, how
they different from each other

Answer Posted / dattatray naikwade

Differential signal voltage level is 0.2V for RS 485 where
as it is +/-3V for RS232.

Is This Answer Correct ?    25 Yes 21 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2217


What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.

2518


Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .

1212


tell me the field & lab calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter, temperature transmitter, temperature indicator, flow indicator, level indicator, control valve, thermocouple, pressure indicator (digital & analogue),

1809


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1579






How many interlocks at turbine side?

1447


principle of dead weight tester ?

1612


Explain the difference between mmwc and mmwg?

3634


What is super thermocoupal?

1705


What is the use of gauge?

700


How is automatic reference junction compensation carried out in temperature recorders?

652


Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd

1645


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

1704


Full form of KKS when use DCS.

2631


What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.

2168