Ans: The material properties of ferromagnetic substances
having great importance in selecting frequency. Frequency
range from 45 Hz to 70 Hz is useable region.
Another consideration is the core and copper loss. In core
loss, the power loss is proportional to frequency, and for
copper loss, is proportional to sq.of frequency.
Developing countries like India, defenitely select the
chepest option, thats 50 HZ.
Another consideration is equipment availablity.
Equipment availibility is only in the range of 50 Hz and 60
Hz. If we chose some other frq. say 70 Hz, Indian
manufactures has to produce accordingly, and that will
create less utilization of ferro magnetic materials.
From above, the conclusion is 50Hz is most suitable and
economical option.
| Is This Answer Correct ? | 78 Yes | 9 No |
Post New Answer View All Answers
How to check the thermocouple is correctly connected to cable for K type? (i,e positive pole is connected to non magnetic conductor and negative pole is connected to magnetic conductor)
working principle of AC Servo Motor with its construction
what is the excess air in furnace
What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)
Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?
Why the cores of large transformers build up of circular cross section?
In HI POT test what is reason for applying the AC VOLTS and DC VOLTS in different applications what is the nessesity for this ?
how to set relay setting? and example calculation...
what is the basic construction diffrance between servo motor ans sqiralcage induction motor
Can i replace Earth leakage relay to the faulty Earth Faulty Relay
Transformer diagram mention each parts ?
Sir, I have applied for the of Assistant.engineer of NPDCL. please send me all AP TRANSCO AND JENCO solved papers of previous exams . I requested send me the papers to my id as soon as possible (rajanikanth_peddi@yahoo.co.in) (This is very urgent) Thank You,
What is the implications when 600 hp motor is started when the unit is running with Transformer of capacity 1500 KVA and DG set of 1000kva
State kirchoff current law?
how to changeover ups in this power failur time?